2000字范文,分享全网优秀范文,学习好帮手!
2000字范文 > 无负压 no negative pressure英语短句 例句大全

无负压 no negative pressure英语短句 例句大全

时间:2024-05-13 11:35:13

相关推荐

无负压 no negative pressure英语短句 例句大全

无负压,no negative pressure

1)no negative pressure无负压

bining the two ways of different water supply schemes,the flow stabilizing water supply mode byno negative pressure was presented in detail from the point of view of energy saving.结合两种不同的供水方案,从节能的角度详细介绍了无负压稳流供水方式,同时结合莱钢金鼎花园实例,阐述了它的工艺流程以及其它的优点等,并提出它在莱钢的适用性和可行性。

英文短句/例句

1.The Applications of No-negative Pressure Water Supply Technique in Medium Rise Buildings谈小高层建筑无负压供水技术的应用

2.Does not have the Negative Pressure(to fold presses) the Feedwater Equipment in High-rise Construction Application无负压(叠压)供水设备在高层建筑中的应用

3.Reforming water supply system based on the water supply equipment of network superposition(no vacuum)利用管网叠压(无负压)供水设备改造供水系统

4.Development and Application of a New Apparatus for Improvement on Induced Abortion;早孕无负压介入流产器械及其术式的研究

5.Analysis and Application of Steady Flow of Water Supply System in Modern Garden Quarter without Vacuum Pressurized Pipe Network现代花园小区无负压管网增压稳流供水系统的分析与应用

6.no-load electro-magnetic valve of air compressor空气压缩机无负荷电磁阀

7.no-load starting electromagnetic valve of air compressor空气压缩机无负荷起动电磁阀

8.Substation Voltage & Reactive Power Control Based on Load Forecasting基于负荷预测的变电站电压无功控制

9.laden with guilt, grief, remorse, etc负咎沉重的、 被悲哀压抑着的、 无限懊恼的.

10.The Application of Load Forecasting in the Substation Voltage and Reactive Power Control负荷预测在变电站电压无功控制中的应用

11.A Strategy for Substation Reactive Voltage Control Based on Active Reactive Load and System Voltage Sections;基于有功无功负荷和系统电压组合分段的变电站电压无功控制策略

12.To load down, burden, or oppress.使负重,使负担或压迫

13.Theca box pressure garge is suit for meassuring pressure of the mediua no corrosion for copper calloys no explode.膜盒压力表适用于测量对铜合金不起腐蚀作用,无爆炸危险的微压和负压。

14.The agent in the unconscious that is responsible for censorship.潜意识压抑力负责抑制潜意识的无意识的作用力

15.The article discusses the transformer allowance to increase the load capacity after reactive compensation and some correlative questions.对无功补偿后变压器允许增加的负载容量及相关问题进行了研讨。

16.It helps us bear our burdens, lessen our tension, overcome our frustration, and dissolve countless trifles and irritations.它帮我们忍耐重负,减轻压力,克服沮丧,解决无数的琐事和烦恼。

17.Design of Voltage Reactive Power Integrated Control System Based on Super Short Term Load Forecast Technology;基于超短期负荷预测技术电压无功综合控制系统设计

18.Control Strategy of Voltage and Reactive Power Based on Peak and Valley Character of Load and Control Parameters;考虑负荷峰谷特性及引入控制参数的电压无功控制策略

相关短句/例句

non-negative pressure method of water supply无负压供水

1.Based on the research work aboutnon-negative pressure method of water supply,it was pointed out that there exist some problems in the system if the facilities are not designed or operated properly,and corresponding engineering measure of how to usenon-negative pressure method of water supply was proposed.对无负压供水技术进行了分析,指出了设计或使用不合理时可能出现的问题;提出了正确使用无负压供水技术的工程措施。

3)non-negative pressure plumb无负压管网

1.Discussion on the withnon-negative pressure plumbing pressurizing and stabilizing system;浅议无负压管网增压稳流供水系统

4)no-load voltage无负载电压

5)no-load pressure无负载压力

6)pipe-network pressure-super-position(non-negative pressure)管网叠压(无负压)

延伸阅读

负压消失的浇注工艺设计原料磨是氧化铝生产的大型设备,主要承担矿浆制备任务,原料磨仓内装φ80~100mm钢球,磨体内衬直径φ2600mm,衬板材质为高锰钢,重67~75kg。衬板表面要求平整光滑,局部凸起≤2mm,铸造尺寸公差±2mm。要求内部质量致密,无影响强度的铸造缺陷。 我单位在用普通砂型铸造原料磨衬板的同时,还利用消失模负压铸造生产该铸件。消失模负压铸造大大提高了该铸件表面光洁度、规整度和尺寸精度,内部组织致密,完全达到铸件装配和使用的质量要求。负压消失模铸造锰钢衬板的工艺设计与以往有很大不同,下面就原料磨衬板浇注系统的设计作一论述。 1.铸造工艺设计原则 (1)控制浇注系统始终呈充满状态 负压消失模铸造的浇注过程是钢水充型的同时塑料模气化消失的过程,浇道若有不充满时,由于涂料层强度有限,极容易发生砂子塌陷,造成铸件缺肉。 (2)控制钢液从底部往上返,利于平稳充型,不容易形成空的内腔。 (3)由于真空的吸力作用,在重力和吸力作用下,钢水充型速度加快,浇注系统适宜偏大些。 2.浇注系统形式 浇注方式选择:立浇,底注,铸件间距70~100mm放一列共13件(1吨炉,钢包容量1吨)。 (1)负压消失模铸造与砂型铸造不同之处在于:一般铸钢件采用开放式,而负压消失模铸造采用封闭式系统,而且,必须是在内浇口处封闭。主要是由于内浇口之前的浇道必须保持充满状态。 (2)内浇口的大小和开设位置 钢水进入模型,塑料模开始燃烧气化消失,液流前端形成暂时的空腔。为防钢水高温辐射熔化模型,形成较大的空型腔,塌砂,所以设计钢水充型的速度和模型消失的速度大致相同,钢水充型速度适宜快。内浇口比以往设计略大。 内浇口的位置选择铸件浇注最低位置上20-30mm处。根据普通砂型铸造的浇注系统设计,计算出内浇口的大小,放大<1/3后,内浇口截面大小为30×2Omm。 为防止铸件与横浇道的离的近,模型高温下变形和熔融,内浇口适当放长,设计长度为5Omm。 (3)横浇道 横浇道截面尺寸70×6Omm。 (4)直浇道 直浇道截面尺寸70×7Omm。 (5)浇口杯 浇注压头大于200-250mm。 一定要设浇口杯。浇口杯的主要作用是积蓄钢水,使直浇道截面瞬时充满,钢水整齐稳定下流。 3.负压度选择 浇注时注意调节和控制负压度在0.02-0.03Mpa范围,浇注后保持在同样的负压度约lOmin。

本内容不代表本网观点和政治立场,如有侵犯你的权益请联系我们处理。
网友评论
网友评论仅供其表达个人看法,并不表明网站立场。