2000字范文,分享全网优秀范文,学习好帮手!
2000字范文 > 接地设计 earthing design英语短句 例句大全

接地设计 earthing design英语短句 例句大全

时间:2020-08-14 20:59:36

相关推荐

接地设计 earthing design英语短句 例句大全

接地设计,earthing design

1)earthing design接地设计

1.This thesis introduces the earthing types of PDS and elaborates in theearthing design of PDS.该文对综合布线系统中的接地类型分别予以了介绍,并对综合布线系统中的接地设计进行了阐述。

英文短句/例句

1.Regulation for design of instrument system grounding仪表系统接地设计规定

2.Code for design of instrument power supply for petrochemical industry石油化工仪表接地设计规范

3.Code for design of lighting protection and earthing of microwave station微波站防雷与接地设计规范

4.Code for design of lightning protection and earthing of mobile communication base stations移动通信基站防雷与接地设计规范

5.Code for design of earthing of industrial and civil electrical installation工业与民用电力装置的接地设计规范

6.Grounding design guide for hydropower station水力发电厂接地设计技术导则

7.Code for design of telecommunications earthing in industrial enterprises工业企业通信接地设计规范

8.Integrated Earthing Design Schema for Open-digged and Shield-digged Tunnel明挖、盾构隧道综合接地设计方案研究

9.Hydraulic Characteristics of Auxiliary Energy Dissipater and its Application in Grounding Design of Tuoxi Hydropower Station Extension Project in Hunan Province湖南省柘溪水电站扩建工程接地设计

10.Grounding Design and Construction of DCS System of Air Separator制氧机DCS系统的接地设计与施工

11.Design of the Protection Device of Ground Fault Line Detection for Neutral Low Current Grounded System;小电流接地系统接地选线装置设计与开发

12.Lightning Protection Design and Frequent Questions in Natural Grounding of Building建筑物自然接地体设计常见问题与防雷设计

13.The Design of Ground Wire Monitoring System Based on GSM Network;基于GSM网络的接地线监测系统的设计

14.Electrode Design and Its Influence Analysis of ±800kV UHVDC System;±800kV直流输电接地极设计及影响分析

15.Research and Design of Ground Access System of Satellite Based on FPGA;基于FPGA的卫星数据地面接入系统设计

16.Design and Implementation of the Connector for the Map Sercvice Platform;地图服务平台中连接器的设计与实现

17.The Design of Optical Receiving System in Monostatic and Bistatic Lidar;单、双基地激光雷达光学接收系统设计

18.Design of DC System Grounding Detecting Device based on LabVIEW基于LabVIEW的直流系统接地检测装置设计

相关短句/例句

Design of Grounding Grid接地网设计

3)design of ground system接地系统设计

4)design of lighting protection and grounding防雷与接地设计

5)preventing thunder earthing design防雷接地设计

1.High buildingpreventing thunder earthing design;高层建筑物的防雷接地设计

6)the design of grounding接地装置设计

延伸阅读

电力系统中性点接地变压器接地电力系统中性点接地变压器接地earthing transformer for neutral groundingd旧n]一x .tong之hongx旧gd一onj旧d一b旧nyoq一j旧d-电力系统中性点接地变压器接地(earthingtransformer for neutral grounding)电力系统中利用接地变压器获得中性点与大地连接,也称中性点辅助变压器接地。当系统中的变压器不具备接人电阻器或接地故障消除器的条件(例如变压器三相绕组为△接线或虽为Y接线但容量不符合要求)时,要利用辅助的变压器提供一个用于接地的中性点。这种变压器应具备零序阻抗低、激磁阻抗大、功率损耗小的特性。绕组为曲折(Z)接线的变压器符合要求,如图1(a)所示。它可以带二次侧绕组,也可以只有一次侧绕组。这种变压器每相由匝数相等的两个串联分绕组组成,每个磁芯上的两个分绕组间以及它们对二次侧绕组的零序互磁为零。很明显,这种变压器的零序电抗XTo只为变压器一次侧绕组的漏电抗Xs,,即XTo-Xs;,而系统中性点与地之间的计算阻抗Z。为Z。一25,+Z。,其中Z。为中性点电阻器或电抗器的阻抗。见图1(b)。2.为激磁阻抗。见图2,YN,d接线的变压器二次侧绕组可以带一定负荷。从过负荷能力考虑已经知道.接YN,d接线的双绕组变压器中性点的接地设备的容t不应超过变压器额定容t的50%.由此可认为,当变压器额定容t按中性点接地设备的容t设计时,允许二次侧绕组带50%额定容t的负荷.还有一种特殊接线的接地变压器和接地设备的组合,是19鲍赫(R.Bauch)发明的,故也称饱鹅变压器,见图3。变压器一次侧中性点直接接地,开口三角形接线的二次侧连接接地设备,这与一次侧中性点接有接地设备是等效的。单相接地时,不对称的电压可分解为对称的正序和零序,磁通也可分解为对应的分量。磁通人m、人。、人.需要极小的激磁电流,并对应于正序电压U.。、U、。、U。。,零序电压UO.对各相是一样的,故三个磁柱中有相同的磁通式,对零序磁通来说,变压器相当一个单相变压器,只不过分裂为3个磁柱和3个绕组,见图3(c)。单相接地时,这种变压器每个分绕组上的电压为少尹z‘一.哟.!|||一下咖l!补丰气l一!{屯犷!{屯享!孟=zl息)一刃川l|拍--l--﹄·图1绕组为曲折(Z)接线的变压器 (a)接线图.(b)零序阻抗图会‘价“相“压,·““”的““是中”点接地“备电流的1/3,即夸。因而变压器的额定功率为3x2‘会‘争即中性点接地设备“率”1.15倍。

本内容不代表本网观点和政治立场,如有侵犯你的权益请联系我们处理。
网友评论
网友评论仅供其表达个人看法,并不表明网站立场。